AMSCO 50 - series 3 - Bay Sink

Department
VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.255-NETWORK CONTRACT OFFICE 15 (36C255)
Country
United States
Closing Date
Not specified
Estimated Value
Not disclosed

Summary

VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.255-NETWORK CONTRACT OFFICE 15 (36C255) is seeking AMSCO 50 - series 3 - Bay Sink. STATEMENT OF WORK The contractor shall furnish all necessary services, labor, travel, transportation, materials, shipping, parts, connections, and equipment. Location: MO.

Full Description

1. STATEMENT OF WORK The contractor shall furnish all necessary services, labor, travel, transportation, materials, shipping, parts, connections, and equipment. This includes the provision and on-site installation of at least 5 AMSCO 50 Series Reprocessing Sinks at 4801 Linwood Blvd, Kansas City MO 64128. These reprocessing sinks are required by the Sterile Processing Services (SPS) to facilitate the manual cleaning of sterilization-compatible reusable medical devices (RMD) in invasive procedures. Their use will support a range of medical procedures and surgeries, including those in the operating room, dental services, procedural gastroenterology, procedural pulmonology and surgical clinics. The contractor bears the responsibility for the removal and disposal of all debris and packaging materials resulting from the reprocessing sinks installation. Prior to equipment utilization, the contractor is required to provide training to clinical staff, with all duty tours for the sterile processing department being documented. The scope of this contract comprises five AMSCO 50 Series Reprocessing Sinks. Associated services include complete installation components, execution of a post-installation check-out test, and implementation of any necessary adjustments. 2. SPECIFICATIONS Minimum of five 3 Bay 97.5” x 28” x 33”- 41” Adjustable Height Reprocessing Sinks. Installer Must Maintain a Minimum Gap of .875” To All Adjacent Walls as a Pinch Point Protection. Unit Must Be Installed Against a Wall, For Back-to-Back Installation a Pony Wall is Required. 304 Stainless Steel Construction. Pony Wall Must Be 53” Wall Must Be Free of Obstructions to 54” Utility requirements (plumbing) Hot Water (HW) Connection Type/Size- 3/8” COMPRESSION Pressure Range- 15 to 125PSI Operating Flow Rate- 1.6GPM @ MAX PSI Temperature Range 40° to 180°F Water Quality- Steris recommends the following water quality parameters: 100-200 PPM (500PPM MAX) TOTAL DISOLVED SOLIDS. 71-120 PPM (180PPM MAX) TOTAL ALKALINITY. 6.8-7.0PH (7.5 MAX). 0.1-0.5PPM (1.0) TOTAL SILICA. Cold Water (CW) Connection Type/Size- 3/8” COMPRESSION Pressure Range- 15 to 125PSI Operating Flow Rate- 1.6GPM @ MAX PSI Temperature Range- 70° F MAX Water Quality- Steris Recommends The Following Water Quality Parameters: 100-200 PPM (500PPM MAX) TOTAL DISOLVED SOLIDS. 71-120 PPM (180PPM MAX) TOTAL ALKALINITY. 6.8-7.0PH (7.5 MAX). 0.1-0.5PPM (1.0) TOTAL SILICA PURE WATER (PW) Connection Type/Size- ½” NPT Pressure Range- 20 TO 125 PSI Operating Flow Rate- .25 TO 2.0 GPM 15% Temperature Range- 40° F to 140° F WATER GUN (WG) Connection type/size- 3/8” Compression Pressure Range- 0 TO 44 PSI Temperature Range- 40° TO 125° Water Quality- Recommendations listed under #5 of (HW & CW) Air Gun (AG) Connection Type/Size- ¼” NPT Pressure Range- 30 PSI MAX Tip 1-5- Tip consumption at 30 PSI (Tip 4 and 5 must be operated at 30 PSI or less to comply with OSHA Directive. Basin Drain (BD) Connection Type- 1-1/2” ABS P-TRAP (INCLUDED), 2” Copper P-Trap (Accessory) Drain Rate At 20 GPM Each Basin (Estimated) Each Drain Individually Trapped When Traps Are Not Required, Elbows Can Be Purchased Locally. Electricity- 120V, 15A GFCI Protected Outlet  LINAK DL2 LIFT SYSTEM Weight Capacity- 562LBS (2500 N) Each Adjustment Range- 8.0” (203.2) Lift Speed- Up To 3/8” (10) Per Second Voltage- 120VAC, 3A With Overload Protection PHYSICAL SPECIFICATIONS Shipping Dimensions- 132Lx 36Wx 48H Shipping Weight- 580LBS Operating Dimensions L x W x H- 97.5” x 28” x 44-9/16” TO 52-9/16” [2477 x 711 x 1132 TO 1412] Concrete Floor Must Remain Free of Defects in These Areas for Installation of Seismic Anchors (Not Provided by Steris). Refer to Equipment Specific Seismic Drawing for More Information. The Reprocessing Sinks must adhere to industry standards for AAMI/ ANSI, OSHA, etc. Documented FDA approval, as applicable. 3. REQUIREMENTS The Contractor is responsible for conducting site visits to verify existing conditions, material quantities, installation instructions, and to identify any discrepancies or conflicting requirements within the Statements of Work before preparing the Final Proposal. The Contractor shall provide and install five AMSCO 50 Series Reprocessing Sinks to the VA Medical Center located at 4801 Linwood Kansas City, Mo 64128.  The Contractor must ensure that all repairs, preventative maintenance and remedial maintenance provided during this contract’s timeframe meet or exceed the OEM’S specifications. The contractor shall employ ONLY FULLY QUALIFIED TECHNICIANS/ENGINEERS for all work performed under this contract.  The contractor shall ensure that only FULLY QUALIFIED TECHNICIANS/ENGINEERS are employed under this contract. The Contractor shall maintain the highest standard of professional capability and workmanship t

Want tenders like this emailed daily?

Get matched government contracts for your industry every morning. Free forever, with plain-English summaries and direct bid links.

Sign Up Free

Similar Tenders