Laser-Safe Enclosure
Department
DEPT OF DEFENSE.DEPT OF THE NAVY.NAVSUP.NAVSUP GLOBAL LOGISTICS SUPPORT.NAVSUP FLC NORFOLK.NAVSUP FLT LOG CTR NORFOLK
Country
United States
Closing Date
Not specified
Estimated Value
Not disclosed
Summary
DEPT OF DEFENSE.DEPT OF THE NAVY.NAVSUP.NAVSUP GLOBAL LOGISTICS SUPPORT.NAVSUP FLC NORFOLK.NAVSUP FLT LOG CTR NORFOLK is seeking Laser-Safe Enclosure. The NAMRU-SA, DEHE Department requires one (1) laser-safe enclosure rated to withstand direct and scattered laser radiation from a 10kW laser, ensuring that radiation levels outside the enclosure… Location: TX.
Full Description
The NAMRU-SA, DEHE Department requires one (1) laser-safe enclosure rated to withstand direct and scattered laser radiation from a 10kW laser, ensuring that radiation levels outside the enclosure remain below the Maximum Permissible Exposure (MPE) limits as defined by relevant safety standards. Specifications: Laser Radiation Protection : To withstand radiation levels of a 10kW laser, the enclosure must utilize material explicitly rated to withstand reflections from a laser powered at 10,000 W/cm, 1060-1070 nm for 10 seconds with a 1 mm beam diameter. This specific threshold provides the necessary barrier against direct or reflected beams from a 10kW source. Safety Interlock System : The enclosure must feature a fully integrated safety interlock system connected to the access door(s). The interlock must automatically disable the laser system's operation immediately upon an access door being opened. Physical Dimensions : The enclosure must provide minimum internal dimensions of 12 feet in length, 12 feet in width, and 10 feet in height (12' L x 12' W x 10' H) to accommodate the laser system, personnel, and associated equipment. Build Design : The enclosure must contain roof and lighting kit. Access Control : The access door mechanism must be designed to restrict entry to authorized and trained personnel only. Environmental Control: The enclosure must be designed to minimize the accumulation of airborne dust and particulates on internal optics and equipment. Standards & Compliance : The enclosure must be delivered with all required safety features to meet or exceed ANSI Z136.1 ("Safe Use of Lasers") standards. This includes, but is not limited to, appropriate warning labels, signage, and emergency procedure information affixed to the enclosure. Warranty Terms : Standard 12-month warranty against defects in material and workmanship.
Want tenders like this emailed daily?
Get matched government contracts for your industry every morning. Free forever, with plain-English summaries and direct bid links.
Sign Up FreeWho won similar contracts
Recent government contract awards from the same buyer or for similar work. Public records from open.canada.ca, SAM.gov, and USAspending.gov.
A similar contract went to SECRET SQUIRREL, LLC for $398,940 in 2026.
DEPT OF DEFENSE.DEPT OF THE NAVY.NAVSUP.NAVSUP GLOBAL LOGISTICS SUPPORT.NAVSUP FLC NORFOLK.NAVSUP FLT LOG CTR NORFOLKU099
A similar contract went to YALE UNIV for $38,188 in 2026.
DEPT OF DEFENSE.DEPT OF THE NAVY.NAVSUP.NAVSUP GLOBAL LOGISTICS SUPPORT.NAVSUP FLC NORFOLK.NAVSUP FLT LOG CTR NORFOLKB537
A similar contract went to RMGS INC for $30,829,266 in 2026.
DEPT OF DEFENSE.DEPT OF THE NAVY.NAVSUP.NAVSUP GLOBAL LOGISTICS SUPPORT.NAVSUP FLC NORFOLK.NAVSUP FLT LOG CTR NORFOLK
A similar contract went to BECKMAN COULTER, INC for $6,030,739 in 2026.
DEPT OF DEFENSE.DEPT OF THE NAVY.NAVSUP.NAVSUP GLOBAL LOGISTICS SUPPORT.NAVSUP FLC NORFOLK.NAVSUP FLT LOG CTR NORFOLK6640
Similar Tenders
PSP Academy Bullet Containment System Remediation
Pennsylvania State PoliceCloses July 6, 2026
Asbestos Removal for Lufkin SSLC
529Closes July 7, 2026
SMD_A&CM_ RFQ #515637 - GROUND SETTLEMENT REMEDIATION at POLO GROUNDS TOWERS…
Housing AuthorityCloses July 7, 2026
Environmental Services
710Closes July 7, 2026
Big Creek Dams Seismic Remediation Design
City of NewportCloses July 7, 2026