MICROWAVE THERAPY SYSTEM

Department
DEPT OF DEFENSE.DEPT OF THE ARMY.US ARMY MEDICAL COMMAND.US ARMY HEALTH CONTRACTING ACTIVITY.W40M USA HCA
Country
United States
Closing Date
Not specified
Estimated Value
Not disclosed

Summary

DEPT OF DEFENSE.DEPT OF THE ARMY.US ARMY MEDICAL COMMAND.US ARMY HEALTH CONTRACTING ACTIVITY.W40M USA HCA is seeking MICROWAVE THERAPY SYSTEM. This is a Request for Information (RFI) – Sought Notice Only. Location: NC.

Full Description

This is a Request for Information (RFI) – Sought Notice Only. This notice is issued solely for information and planning purposes only.   1. The US Government will not pay for any information or administrative costs incurred in response to this notice. Submittals will not be returned to the responder; not responding to this notice does not preclude participation in any further RFQ; IFB or RFP if issued.   2. The associated North American Industry Classification System (NAICS) is 334510. The business size standard is 750 Employees. All contractors doing business with the Department of Defense shall be registered and approved through the System for Award Management (SAM). This is the Official U.S. Government system that consolidates the capabilities of CCR/FedReg, and EPLS. There is no fee to register for this site. Entities may register at no cost directly from this page. The proposed performance start date will be on or about 1 July 2026. The Solicitation number is W81K0426QA043.   3. Note – Prior to award your company shall reflect the NAICS Code 334510 identified on your SAM. If your company is interested in competing on this project, and have services, please submit the following documentation no later than  21 May 2026, 10:00 AM EST, to Cynthia A. Richardson-Rhone and Jason Holck at cynthia.a.richardson-rhone.civ@health.mil .  Your email response shall provide the following: Can you provide the following: General System Description The Intelli Blate Microwave Ablation System is a software-controlled microwave therapy delivery platform intended for the coagulation (ablation) of soft tissues. The system utilizes microwave energy to produce controlled, spherical ablation zones and features integrated cooling, real-time temperature monitoring, and advanced probe placement functions. Generator (Console) Specifications Operating Frequency  2.45 GHz ± 50 MHz Ablation Channels       Must support at least two (2) independent ablation channels, allowing for single-probe, dual-independent, or dual-linked probe operations Output Power  Single Channel: 0 to 90 Watts. Dual Channel: 0 to 80 Watts per channel (up to 160 Watts linked) Power Adjustments     Output power must be adjustable in 5-Watt increments. Safety Shut off            Must feature an automatic system shutdown if probe temperatures or reflected power exceed established safety limits Dimensions & Weight Console alone must weigh no more than 40 lbs. (approx. 38 lbs.) for portability and mount securely to a customized mobile cart User Interface & Display Monitor            15.6-inch foldable, high-resolution color touchscreen Ergonomics     Screen must be capable of swiveling 180 degrees (CW/CCW) to allow visibility from any operating position. Must be fully operable with gloved hands or through a sterile drape Visual Feedback         Interface must provide real-time tracking of time, tip power, reflected energy (power), and multi-point temperature data Integrated Cooling System Pump Mechanism       Must feature two (2) fully integrated peristaltic pumps built directly into the console (one for each ablation channel) Coolant Compatibility Must be compatible with standard, user-supplied sterile water or 0.9% saline (1000 mL bags or greater) Cassette Loading        Must utilize a drop-in, integrated fluid cassette system to streamline coolant delivery and prevent setup errors Probe Assembly Characteristics (Ximitry Probes) Antenna Profile           13.5 Gauge (2.3 mm diameter) fiberglass shaft with a ceramic trocar tip Available Lengths       Must be available in at least three lengths: 15 cm, 20 cm, and 27 cm Integrated Temperature Sensing        Probe must contain at least three (3) integrated thermocouples along the shaft and two (2) internal temperature sensors within the handle for continuous, real-time thermal feedback Cable Management    Must utilize a single-cable bundle that integrates both the RF power cable and the coolant tubing (supply and return lines) into one cord Visual Indicators         Probe handles must include integrated LED indicators to visually signal when microwave energy is actively being delivered Advanced Clinical Workflow Features Needle Lock    Must include a feature that delivers a short, calculated burst of microwave energy to secure the radiating section of the probe to the tissue, mitigating accidental probe migration during setup or intra-procedural imaging Tract Ablation  Must include a specific

Want tenders like this emailed daily?

Get matched government contracts for your industry every morning. Free forever, with plain-English summaries and direct bid links.

Sign Up Free

Similar Tenders