J041--Dietetics Walk-In Freezer Replacement

Department
VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.241-NETWORK CONTRACT OFFICE 01 (36C241)
Country
United States
Closing Date
Not specified
Estimated Value
Not disclosed

Summary

VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.241-NETWORK CONTRACT OFFICE 01 (36C241) is seeking J041--Dietetics Walk-In Freezer Replacement. Combined Synopsis-Solicitation for Commercial Products and Commercial Services Effective Date: 04/18/2025 Revision: 02 THE PURPOSE OF THIS AMENDMENT IS TO SET A SITE VISIT: Date - MAY 20, 2026 @ 10am . Location: VT.

Full Description

Combined Synopsis-Solicitation for Commercial Products and Commercial Services Effective Date: 04/18/2025 Revision: 02 THE PURPOSE OF THIS AMENDMENT IS TO SET A SITE VISIT: Date - MAY 20, 2026 @ 10am Building - 37 POC - Robert Mallinson Description This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2025-04. This solicitation is set-aside for SDVOSB The associated North American Industrial Classification System (NAICS) code for this procurement is 333415, with a small business size standard of 1250 Employees. The FSC/PSC is J041. The White River Junction VAMC located at 163 Veterans Drive is seeking a qualified vendor to provide a Dietetics Walk-In Freezer Replacement IAW the SOW. All interested companies shall provide quotations for the following: Supplies/Services ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 Dietetics Walk-In Freezer Replacement IAW the SOW Period: Base 1.00 EA __________________ __________________ STATEMENT OF WORK (SOW) Dietetics Walk-In Freezer Replacement Department of Veterans Affairs White River Junction VAMC Project Scope The White River Junction VA Healthcare System requires the services of a qualified firm to upgrade the refrigeration components of the dietetics walk-in freezer. It has been determined that the cabinet of the existing freezer is in sufficient condition, therefore entire box replacement is not necessary. Contractor shall ensure that the removal process of the old components does not damage the structure of the walk-in freezer. Condenser is housed inside an enclosure on the roof. Use of a crane will be necessary for the safe removal of existing equipment, and proper installation of the new equipment. Contractor will need to cut into enclosure to perform work. Contractor will be responsible for disassembly and reassembly of structure. Current structure is made of wood with metal siding. Contractor shall be responsible for confirming that the cooling capacity for the system is sufficient. Current capacity is 36,410 BTU. Contractor shall be responsible for all electrical attached to this project. Voltage of current equipment is 208/230. This will include confirming the new equipment does not exceed the available amperage. If new equipment does exceed the available amperage, contractor shall work with onsite facilities staff to find solutions or choose other equipment. Contractor shall provide and install a refrigerant that is appropriate for low-temperature applications and meets all current industry standards, codes, and manufacturer requirements for walk-in freezers operating in the range of minus 10 to minus 20 degrees. Contractor shall provide submittals of proposed equipment. The VA Medical Center reserves the right to deny proposed equipment if it does not meet the necessary requirements Contractor shall confirm system is operating sufficiently, keeping the temperature within the freezer at the appropriate required temperature. It is recommended that vendors perform a site visit to better assess existing conditions. Tasks Removal of existing equipment. Contractors shall be responsible for adhering to all regulations regarding the removal, pump-down, and disposal of current equipment. Contractor shall provide a report that includes amount of refrigerant removed. Demolition of unnecessary control and line voltage wiring. Existing equipment information: Condenser Heatcraft, model # BDT0750L6C, serial # T06L00946 Evaporator Heatcraft, model # BML250BA, serial # D06K04939 Install new evaporator, condenser, piping, time clock, and all other refrigeration components. Evaporator Contractor shall ensure the installation adheres to manufacturer s instructions. Condenser Installation shall include anti vibration solutions to limit transmission of vibration through building. Refrigeration piping All existing refrigeration piping shall be replaced. Due to the catastrophic failure of existing equipment, the VA Medical Center HVAC team has concerns that attempting to reuse current piping, even if purged, will compromise new equipment. Therefore, use of current refrigeration piping will not be permitted. Piping shall be properly insulated and supported in accordance with industry standards. Contractor shall ensure after piping connections are made, proper leak test procedures are performed. Contractor shall perform appropriate vacuum procedures on syst

Want tenders like this emailed daily?

Get matched government contracts for your industry every morning. Free forever, with plain-English summaries and direct bid links.

Sign Up Free

Similar Tenders