Pre Solicitation Notice PACS Preventive Maintenance *THIS WILL BE A 100% SDVOSB SET ASIDE* Department of Veterans Affairs (VA)
Physical Access Control System (PACS) Preventative Maintenance SCOPE: The Contractor shall provide all personnel, equipment, tools, material, supervision, and quality control necessary to perform preventative maintenance, inspections and updates/upgrades to the Physical Access Control System (PACS) equipment at the Department of Veterans Affairs, (Veterans Benefits Administration Winston-Salem Regional Office). PLACE OF PERFORMANCE / HOURS OF OPERATION: Department of Veterans Affairs Regional Office 251 North Main Street
Winston-Salem, NC 27155 Normal Business Hours are 7:00 AM EST to 4:00 PM EST. All work will be performed during normal operation hours: Work at the site will not take place on Federal Holidays or weekends. If a Federal Holiday falls on a day scheduled for services, the services will resume the next official workday between the scheduled hours. Vendor shall contact the facility Point of Contract (POC) at least one hour prior to arrival to the station by calling the POC s direct extension. PERIOD OF PERFORMANCE: The period of performance shall be one (1) base year (12 months) with four (4) potential (1) option years to be exercised at the discretion of the Contracting Officer. Government Furnished Equipment: Lenel Physical Access Control System (PACS) OnGuard security systems POST AWARD MEETINGS / PROGRESS MEETINGS: The contractor shall attend (virtually) any post award meetings convened by the Contracting Officer (CO), Contract Specialist (CS) or facility POC. Meetings shall discuss contract performance, lessons learned, issues identified or any other topic deemed necessary by the Government. Contractors attendance at these meetings shall be at no additional cost to the Government. CONTRACTOR QUALIFICATIONS: The contractor or subcontractor shall be a certified and approved reseller for Lenel Physical Access Control System (PACS) OnGuard security systems and HID smart card readers for the duration of the contract term. PREVENTATIVE MAINTENANCE: The Contractor shall provide services required under this contract within normal business hours which are 7:00 AM EST to 4:00 PM EST, Monday through Friday, except on recognized federal holidays or when the Government facility is closed due to local/national emergencies, administrative closures, or similar Government directed facility closings. The first inspection shall take place within 30 business days of the period of performance start date, each following inspection will take place every six (6) months, unless otherwise approved by the facility POC. Provide preventative maintenance on a day mutually agreed on by the Government and the contractor for the devices indicated on the Equipment Inventory List. Equipment List: Equipment Inventory List
Item No. Part Number:
Description:
Quantity:
1
921PHRTEK0032W
PIV Smart Keypad Reader
10
2
SE R40
HID PIV Smart Card Reader
41
3
SY-DV16RD-E8M2-NET
Life Safety Power Genetec Enclosure
3
4
SY-MR52-S3
Dual Card Reader Interface
3
5
LP4502
HID intelligent controller 3
6
CLOUDLINK G2
Smart Gateway
3
7
OptiPlex 3080
Dell Tower
1
8
Intellinet
5-Port Ethernet Switch
2
9
ML7.2
12V Battery
6 Twice (2) times a year - Verify functionality of access control doors, duress/panic buttons and head end equipment. Twice (2) times a year - Perform back up of the system database. Twice (2) times a year Conduct software maintenance and functionality tests to include installation of software updates / patches to all equipment. Provide manufacturer software technical help desk support and update support as needed at no additional cost to the Government. Twice (2) times a year - Perform preventive maintenance inspections of the security system. Maintenance inspection shall include but not limited to:
Operational testing of all PACS equipment. Load Testing of all power supplies and back-up batteries in all systems, Cleaning and adjusting of all equipment
Checking equipment for loose mountings or connections, adjusting electric locks, etc. PREVENTATIVE MAINTENANCE REPORTING: Within ten (10) business days of the inspection date, the Contractor shall prepare and submit to the facility POC a written report and shall include but not limited to: Name of Employee providing services Date and time of service Operational test results to include but not limited to access control doors/panic buttons.
All deficiencies shall include type, location, part number, test results and quote for repair. Results of power supply and back-up battery tests. All deficiencies shall include type, location, part number, test results and quote for repair. Equipment Adjustments.
List, locations, part numbers, and adjustments made. System database back-up.
Date and time of back-up. Software maintenance / function check.
Software manufacturer s name, software name, software version prior to update, software version after update. Description